ETFE

AGL LI7YC7Y NC IEC 1 x 2 x 0.75

AGL LI7YC7Y NC IEC 1 x 2 x 0.75 acc. to DIN IEC 60584
Construction
  • Conductor: compensation alloy for NiCroSil-NiSil, NC IEC; 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: pink (+) and white (-)
  • Filler: silicone rubber (round shaping)
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Outer sheath: ETFE; colour: pink

AGL LI7YC7Y KCA IEC n x 2 x 0.75

AGL LI7YC7Y KCA IEC n x 2 x 0.75 acc. to DIN IEC 60584
Application

Compensation cable KCA for temperature sensors

Construction
  • Conductor: compensation alloy for NiCr-Ni, KCA IEC (Fe-CuNi); 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: green (+) and white (-)
    from 2 x 2 x 0.75: additional pairs with bar code
  • Filler: silicone rubber (round shaping), from 4 x 2 x 0.75 glass fibre
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Outer sheath: ETFE; colour: green

AGL LI7YC7Y KCA IEC 2 x 2 x 0.75 nr

AGL LI7YC7Y KCA IEC 2 x 2 x 0.75 nr acc. to DIN IEC 60584
Application

Compensation cable KCA for temperature sensors

Construction
  • Conductor: compensation alloy for NiCr-Ni, KCA IEC (Fe-CuNi); 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.6 ± 0.05 mm
  • Core identification: green (+) and white (-); bar code on 1 pair
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Outer sheath: ETFE; colour: green

AGL LI7YC7Y KCA IEC n x 2 x 1.0

AGL LI7YC7Y KCA IEC n x 2 x 1.0 acc. to DIN IEC 60584
Application

Compensation cable KCA for temperature sensors

Construction
  • Conductor: compensation alloy for NiCr-Ni; KCA IEC (Fe-CuNi); 32 x 0.2 mm = 1.0 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.77 ± 0.05 mm
  • Core identification: green (+) and white (-),
    from 2 x 2 x 1.0: additional pairs with bar code
  • Filler: silicone rubber (round shaping)
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Outer sheath: ETFE; colour: green

AGL LI7YC7YS7Y KCA IEC n x 2 x 0.75

AGL LI7YC7YS7Y KCA IEC n x 2 x 0.75 acc. to DIN IEC 60584
Application

Compensation cable KCA for temperature sensors

Construction
  • Conductor: compensation alloy for NiCr-Ni, KCA IEC (Fe-CuNi); 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: green (+) and white (-),
    from 1 x 2 x 0.75: additional pairs with bar code
  • Filler: silicone rubber (round shaping), from 4 x 2 x 0.75 glass fibre
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Sheath: ETFE
  • Armouring: galvanized steel wire braid (Ø 0.2 mm)
  • Outer sheath: ETFE; colour: green

THL LI7YC7Y TX IEC n x 2 x 0.75

THL LI7YC7Y TX IEC n x 2 x 0.75 acc. to DIN IEC 60584
Anwendung

Thermo extension cable TX for temperature sensors

Construction
  • Conductor: thermo extension alloy Cu-CuNi, TX IEC; 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: brown (+) and white (-),
    from 2 x 2 x 0.75: additional pairs with bar code
  • Filler: silicone rubber (round shaping)
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85%
  • Outer sheath: ETFE; colour: brown

THL LI7YC7Y EX IEC n x 2 x 0.75

THL LI7YC7Y EX IEC n x 2 x 0.75 acc. to DIN IEC 60584
Application

Thermo extension cable EX for temperature sensors

Construction
  • Conductor: thermo extension alloy NiCr-CuNi, EX IEC; 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE, wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: purple (+) and white (-),
    from 2 x 2 x 0.75: additional pairs with bar code
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85%
  • Outer sheath: ETFE; colour: purple

THL LI7YC7Y JX IEC n x 2 x 0.75

THL LI7YC7Y JX IEC n x 2 x 0.75 acc. to DIN IEC 60584
Application

Thermo extension cable JX for temperature sensors

Construction
  • Conductor: thermo extension alloy Fe-CuNi, JX IEC; 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: black (+) and white (-),
    from 2 x 2 x 0.75: additional pairs with bar code
  • Filler: silicone rubber (round shaping)
  • Lapping: polyester tape
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Outer sheath: ETFE; colour: black

THL LI7YC7YS7Y JX IEC n x 2 x 0.75

THL LI7YC7YS7Y JX IEC n x 2 x 0.75 nach DIN IEC 60584
Application

Thermo extension cable JX for temperature sensors

Construction
  • Conductor: thermo extension alloy Fe-CuNi, JX IEC; 24 x 0.2 mm = 0.75 mm²
  • Core insulation: ETFE; wall thickness 0.25 mm; Ø 1.65 ± 0.05 mm
  • Core identification: black (+) and white (-),
    from 2 x 2 x 0.75: additional pairs with bar code
  • Filler: silicone rubber (round shaping)
  • Screen: tinned copper wire braid; optical coverage approx. 85 %
  • Sheath: ETFE
  • Armouring: galvanized steel wire braid (Ø 0.2 mm)
  • Outer sheath: ETFE, colour: black
Back to top